Home  |  About Us  |  Products  |  Certificates  |  Events  |  Feed Back  |  Contact Us  |  Email  |  Site Map
 
 
RESEARCH AIDS
     
 
  OPTICA CELLS (CUVETTES)
410M OPTICA CELLS FOR UV SPECTROPHOTOMETER - QUARTZ
410M OPTICA CELLS FOR UV SPECTROPHOTOMETER - QUARTZ
410M OPTICA CELLS FOR UV SPECTROPHOTOMETER - QUARTZ
TWO SIDE POLISHED WITH PTFE COVERS FLAT FROM BOTTOM
Cat No. Optial Path
Length mm
External
Size (mm)
Capacity ml

SQ0350
SQ0700
SQ1400
SQ1750
SQ3500
SQ0140
SQ0100

SQ0070
SQ0035

10 mm
20 mm
40 mm
50 mm
100 mm
Oblique midget
(Black) 10 mm
Oblique midget
10 mm 
1mm

12.5x12.5x45
12.5x22.5x45
12.5x42.5x45
12.5x52.5x45
12.5x102.5x45
12.5x12.5x45
12.5x12.5x45

12.5x12.5x45
12.5x3.5x45

3.50 ml
7.00 ml
14.00 ml
17.50 ml
35.00 ml
1.40 ml
1.00 ml

0.7 ml
0.35 ml

   
411M OPTICA CELLS FOR UV SPECTROPHOTOMETER - GLASS
411M OPTICA CELLS FOR UV SPECTROPHOTOMETER - GLASS
TWO SIDE POLISHED WITH PTFE COVERS FLAT FROM BOTTOM
Cat No. Optial Path
Length mm
External
Size (mm)
Capacity ml

SG0350
SG0700
SG1400
SG1750
SG3500
SSG0140

SG0070

10 mm
20 mm
40 mm
50 mm
100 mm
Oblique midget
(Black) 10 mm
10 mm 

12.5x12.5x45
12.5x22.5x45
12.5x42.5x45
12.5x52.5x45
12.5x102.5x45
12.5x12.5x45

12.5x12.5x45

3.50 ml
7.00 ml
14.00 ml
17.50 ml
35.00 ml
1.40 ml

0.7 ml

   
412M CELL FOR FLOURIMETER - QUARTZ
412M CELL FOR FLOURIMETER - QUARTZ
All Four Sides Polished with PTFE Covers
Cat No. Capacity ml Path Length Type

FQ0350
FQ0140
FQ0050

3.5 ml
1.4 ml
0.5 ml

10mm
10mm
10mm

macro
micro
micro

   
413M CELL FOR FLOURIMETER - GLASS
413M CELL FOR FLOURIMETER - GLASS
All Four Sides Polished with PTFE Covers
Cat No. Capacity ml Path Length Type

FG0350
FG0140
FG0050

3.5 ml
1.4 ml
0.5 ml

10mm
10mm
10mm

macro
micro
micro

   
       

414M OPTICA CYLINDERICAL CELLS
414M OPTICA CYLINDERICAL CELLS
with PTFE lid all sides polished.

Polarimetric Measurement For some applications, e.g. in polarimetry and for circular dichroism measurements, it is important to check that the cells are free of strain birefringence. The effect of possible strain birefringence is determined in the following way: In a polarimeter the rotation of the plane of polarisation of the incident linearly polarised light ist measured. The measurement is carried out in a circular area of approximately 3 mm diameter whose centre coincides with the
centre height of the empty cell. Because of the measuring geometry, only cells with an aperture diameter or aperture width of greater than 3 mm can be measured in this way.

Cat No. Dia (mm) Path Length Type

PQ010

22mm

10mm

macro

   


 
All right reserved. © www.axivasichem.com
Designed & Developed by S.D. (India) Corporation